Model TR25
Model TR25
Applications
- Food and beverage industry, dairies, drink dispensers and bottling plants, breweries
- Biochemical and pharmaceutical industries, cleanroom technology
- For piggable systems
- Paint finishing systems
Special Features
- Hygienic design (dead space free transitions)
- Residue-free and quick cleaning of the measuring point (piggable, suitable for SIP and CIP)
- Materials and surface qualities in accordance with the standards and directives of the pharmaceutical industry
- High measuring accuracy with shortresponse times
- Explosion-proof versions Ex i
Resistance thermometers for temperature measurement in pipelines with extremely high hygienic requirements. This thermometer is used in applications where a thermowell immersed into the process medium is not possible or not desired, particularly for piggable pipelines, highly viscous media and flow conditions with high shear forces. A wide variety of process connections is available, so that these thermometers can be used for many different processes without any problems.
3- or 4-wire platinum measurement resistances in accuracy classes A and B per DIN EN 60751 serve as sensors.
Analogue or digital transmitters built into the connection head are capable of making various output signals available, for example 4 ... 20 mA, HART® protocol, FOUNDATION™ fieldbus or PROFIBUS® PA.